Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 1 of 16
MRO Delay Line ICD
Metrology System to Beam Combining Facility
ICD INT-406-VEN-0012
The Cambridge Delay Line Team
rev 0.4
5 October 2009
Cavendish Laboratory
JJ Thomson Avenue
Cambridge CB3 0HE
UK
Vista de pagina 0
1 2 3 4 5 6 ... 15 16

Indice de contenidos

Pagina 1 - MRO Delay Line ICD

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 1 of 16 MRO Delay Line ICD Metrology System to Beam Combining Facil

Pagina 2 - 3 Notification List

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 10 of 16 INNER BCA DELAY LINES OUTER BCA METROLOGY BENCH N SOUTH W

Pagina 3 - 4 Scope

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 11 of 16 Figure 2 Position of the top surface of the metrology tab

Pagina 4 - 8 Introduction

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 12 of 16 Figure 3 The Agilent cable arrangement for laser head, po

Pagina 5 - 9 Requirements

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 13 of 16 Figure 4 The Agilent 10881C Laser head cable. 13

Pagina 6 - 9.3 Cabling

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 14 of 16 Figure 5 Specification sheet for the Agilent 5517FL laser

Pagina 7 - 10 Design

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 15 of 16 Figure 7 Specification sheet for the Agilent 5517GL laser

Pagina 8

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 16 of 16 Figure 8 Extract from Agilent Laser System User Manual 1

Pagina 9 - 11 Appendix

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 2 of 16 1 ICD Description ICD Number Sub-systems Org Owner Br

Pagina 10

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 3 of 16 Table of Contents 1 ICD Description...

Pagina 11

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 4 of 16 6 Applicable Documents DOCUMENTS AD1 Top Level Requirem

Pagina 12

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 5 of 16 9 Requirements 9.1 Metrology Table 9.1.1 Metrology

Pagina 13

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 6 of 16 Table 1 Electronics in the rack positioned in the outer BCA

Pagina 14

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 7 of 16 9.4 Services The following services are required for the

Pagina 15

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 8 of 16 is supplied via the measurement board to which they connect

Pagina 16

Metrology System to Beam Combining Facility ICD INT-406-VEN-0012 v0.4.doc Page 9 of 16 10.3 Laser cooling To prevent uncontrolled air exchange

Comentarios a estos manuales

Sin comentarios